What you need to know about NetApp’s 40GbE options

­With the introduction of the new NetApp platforms back in September 2016, came 40GbE as well as 32Gb Fibre Channel connectivity.

I had my first taste of 40GbE on the NetApp side back in January when I got to install the first All Flash FAS A700 in Canada. The client requested a mix of 40GbE and 16Gb FC with some of the 40GbE being broken out into 4 × 10GbE interfaces and some being used natively.

NetApp is deploying two flavours of 40GbE cards: the X1144A for the AFF A300, AFF A700s and FAS8200, and the X91440A for the AFF A700 and FAS9000 storage systems. At first glance, you might be tempted to assume that those are the same PCIe card since the part numbers are very similar (the latter just being in some sort of carrier to satisfy the I/O module requirement for the blade-style chassis that is home to the A700 and FAS9000), Upon further inspection the two are not exactly equal.

The ports on most PCIe cards and onboard interfaces are deployed in pairs, with one shared application-specific integrated circuit (ASIC) on the board behind the physical ports. On the X1144A, both external ports share one ASIC with an available combined bandwidth of 40Gb/s, whereas the X91440A has two ASICs. Each has two ports, but one is internal and not connected to anything, giving you 40Gb/s per external port.

The ASIC (or controller) in question is the Intel XL710. What’s important about this is that both external ports on an X91440A can be broken out to 4 × 10GbE interfaces for a total of eight, or one can remain at 40GbE while the other is broken out. On the X1144A however, you can either connect both ports to your switch using 40GbE connections or you can break-out port A to 4 × 10GbE and port B gets disabled. According to Intel, if you connect both ports via 40GbE, “The total throughput supported by the 710 series is 40 Gb/s, even when connected via two 40 Gb/s connections.”

Now before we get all up in arms about this, lets really get into the weeds here. Both the FAS8200/FAS9000 and the AFF A300/700 are using PCIe 3.0. Each PCIe 3.0 lane can carry 8 Gigatransfers per second (GT/s). For the purposes of this post, that is close enough to 8Gb/s. The FAS8200/AFF A300 has an Intel D-1587 CPU with a maximum eight lanes per slot, so roughly 64Gb/s of throughput, whereas the FAS9000/AFF A700 has an Intel E5-2697 with a maximum 16 lanes per I/O slot which gives it about 128Gb/s of throughput. So even if NetApp included a network interface card for the A300/FAS8200 with two XL710’s on it, the PCIe slot it’s connected to couldn’t provide 80Gb/s of throughput, whereas the the I/O modules in the A700/FAS9000 can.

Say you want to change between 40GbE and 10GbE. Unlike modifying UTA2 profiles (as explained here), with the XL710, you need to get into maintenance mode first and use the nicadmin command. Here’s an example:

sysconfig output before:

slot 1: 40 Gigabit Ethernet Controller XL710 QSFP+
                 e1a MAC Address:    00:a0:98:c5:b2:fb (auto-40g_cr4-fd-up)
                 e1e MAC Address:    00:a0:98:c5:b2:ff (auto-unknown-down)

At this point I already had the breakout cable installed. That’s why the second link shows as down.

Conversion example:

*> nicadmin
 nicadmin convert -m { 40G | 10G } <port-name>
 
 
 *> nicadmin convert -m 10g e1e
 Converting e1e 40G port to four 10G ports
 Halt, install/change the cable, and then power-cycle the node for
 the conversion to take effect.  Depending on the hardware model,
 the SP (Service Processor) or BMC (Baseboard Management Controller)
 can be used to power-cycle the node.

sysconfig output after:

slot 1: 40 Gigabit Ethernet Controller XL710 QSFP+
                 e1a MAC Address:    00:a0:98:c5:b2:fb (auto-40g_cr4-fd-up)
                 e1e MAC Address:    00:a0:98:c5:b2:ff (auto-10g_twinax-fd-up)
                 e1f MAC Address:    00:a0:98:c5:b3:00 (auto-10g_twinax-fd-up)
                 e1g MAC Address:    00:a0:98:c5:b3:01 (auto-10g_twinax-fd-up)
                 e1h MAC Address:    00:a0:98:c5:b3:02 (auto-10g_twinax-fd-up)

Unfortunately I don’t have access to either a FAS8200 nor an AFF A300 with 40GbE otherwise I’d provide the sysconfig output before and after there as well.

Now, there’s a bit of a debate going on around the viability of 40GbE over 100GbE. While 40GbE is simply a combined 4 × 10GbE; 100GbE is only a combined 4 × 25GbE. With regards to production costs, apparently to make a 40GbE QSFP+, you literally combine 4 lasers (hence the Q in QSFP) into the module; well, the same goes for 100GbE. You only need one laser to produce the wavelength for 25GbE, and while that still means you need four for 100GbE, four times the production cost still yields 250% of the throughput of 40GbE which makes me wonder where it will end up in a year.

So there you go, more than you ever wanted to know about NetApp’s recent addition of 40GbE into the ONTAP line of products as well as my personal philosophical waxing around the 40 versus 100 GbE debate.

3 thoughts on “What you need to know about NetApp’s 40GbE options

  1. Bytegab

    Great info, thanks for taking the time to put it out there! I’m working on an A300 config, was originally going to make 2 of the onboard UTA2’s 10GbE and the other 2 UTA2’s FC. This would provide 4 x 10G and 4 x FC for the system. Was then going to add 4-port UTA2 cards to one of the 2 available slots and do an additional four of each, for total of 8 x 10G and 8 x FC.

    Alternately, I’m thinking of using the 4 onboard UTA2’s all for FC, and then add a 40G card per slot and use the breakout cable to get 4 x 10G per head. This results in the same 8 x FC and 8 x 10G above, but in the future if they u/g their Ethernet infrastructure to 40G we can pull off the breakout cable and give them the option to go 40G right into their upgraded Ethernet environment.

    Pros/cons? With only one active 40G port with A300, that would be a single path per controller, perhaps more robust since 40G isn’t in their immediate future to stay with the first option.

    Thanks again for posting this, helped me understand more around the ASICs etc.

    Reply
    1. Bytegab

      Sorry for spamming your blog, per HWU I’m going to roll with 4 x 10G using onboards per controller and add in (2) 4-port FC HBA one per controller. In the end will provide 8 x 10GbE plus 8 x 16Gb/s FC. I’m going to compare this config vs. using all 8 onboard UTA2’s with 16Gb/s FC SFP+ modules, and adding in a 40G adapter per head with breakout cables. End result of each will be same 8 x 10G and 8 x FC.

      Reply

Leave a Reply